5. Inspection Requirements & Checklists

Outlines mandatory inspection frequencies and procedures. Provides guidance on checking frames, braces, platforms, castors, and stabilisers to identify defects before use or after changes.

5.1 Mandatory Inspections

​

  • Before first use

  • After every modification

  • After relocation

  • After severe weather

  • Minimum every 7 days

 

5.2 Equipment Inspection Checklist

Inspect all of the following:

 

Frames

  • No bends, cracks, or corrosion

  • Couplers intact

 

Braces

  • Straight

  • Locking claws functional

 

Platforms

  • No rot, cracks, delamination

  • Latches functional

 

Castors

  • Brakes operate fully

  • No excessive wear

 

Stabilisers

  • Joints move freely

  • Rubber footpads intact